Download Reverse Osmosis Nd Manual PDF

TitleReverse Osmosis Nd Manual
File Size2.2 MB
Total Pages102
Document Text Contents
Page 2

Overview of contents

General information A
Transport and storage B
Technical data/ product description C
Set-up and assembly D
Placing the system in service / taking it out of service E
Operation / monitoring F
Malfunctions G
Maintenance H
Preserving/Cleaning the system I


Appendix


- R+I flowchart with components and spare parts list
- Circuit diagram
- Control system manual
- Operating Instructions options












Imprint
All Rights Reserved.



The edition date on the cover sheet is definitive.
Subject to technical changes.

These Operating Instructions may not be translated into foreign
languages, reprinted, saved on data media or otherwise duplicated
except with the express written approval of the manufacter.














File: BA_GB_DB_UOND43-120_0506_A.doc
Dec 12, 2006/Mü

Page 101

RO 1000 - Version 1.12 MANUAL


10.01.96 Page 24/24


5. Technical Data



The following table contains all significant technical data of the RO 1000 control.



min. type max. unit

nominal service voltage
main frequenCy
nominal voltamps

200
47
5

230
-
-

260
63
10

V
Hz
VA

ambient temperature range (operation)
ambient temperature range (storage)
relative air humidity

0
-10
15

-
-
-

50
70
85

° C
° C
%

conductivity range
- accuraCy of measurement (ref. to range end
value without sensor)
- temperature range

2
-


0

-
0.5


-

200
1


40

µS/cm
%


° C

switching current of circuit inputs
adm. relay load for 230 V AC
adm. relay load for 24 V DC
total installed load
total installed load - solenoid valves

0
-
-
-
-

-
-
-
-
-

30
4
1

1000
250

mA
A
A

VA
VA

protection class IP55

Page 102

Settings RO 1000 Control

1 Ackn.failure

2 Operat.mode STOP When various settings possible the factory
OPERATION adjustment is the first on the following
DISINFECTION menue table.

3 cy-permeate

4 temperature

5 hour meter

6 cy-limits lim: 050 µS/cm
war: 040 µS/cm

7 ps lim. exc. do no stop
do stop

8 calibration 1 temp. permeate XX.X: °C

2 cy-permeate 1 cond UNTEN XXX µS/cm

2 cond OBEN XXX µS/cm

3 calibr.-reset

9 settings 1 t-delay-LIM 05 min

2 t-del.aa-LIM 01 min

3 t-low pressure 01 s (8 s)*

4 t-press.hys 9,9 s

5 t-press.TO 60 s

6 t-disc. rinse 00 min

7 t-inter rinse 00 h

8 t-concentrate 01 min

9 t-disposal min: max:
005 s 60 min

10 t-maintenance 003500 h

11 ps-acknowl. without password
only with password

12 ps-concentrate displacement
rinse

13 ps-tank-type with overflow
no overflow

14 inputs 1 extern.stop normally opend
normally closed

2 motor ptotection normally opend
normally closed

3 pressure switch normally opend
normally closed

4 tank min not active
normally opend
normally closed

5 tank max normally opend
normally closed

15 language english
deutsch

16 syst.-reset

10 diagnostic 1 digit.input
2 digit.output * for 3-phase current/RO pump
3 lights
4 cy-permeate
5 temp.-permeate

Stand: 03.09.03/Sw, Datei: Settings RO1000.xls