Download ONE STAGE LIGHT OIL BURNERS - PT. Arindo Prima Lestari | Leading PDF

TitleONE STAGE LIGHT OIL BURNERS - PT. Arindo Prima Lestari | Leading
LanguageEnglish
File Size9.3 MB
Total Pages327
Document Text Contents
Page 1

The Riello 40 G series of one stage light oil burners, is a complete range of productsdeveloped to respond to any request for home heating. The Riello 40 G series is availablein eleven different models, whit an output ranging from 12 to 240 kW, divided in fourdifferent structures.All the models use the same components designed by Riello for the Riello 40 G series. Thehigh quality level guarantees safe working.In developing these burners, special attention was paid to reducing noise, to the ease ofinstallation and adjustment, to obtaining the smallest size possible to fit into any sort ofboiler available on the market.All the models are approved by the EN 267 European Standard and conform to EuropeanDirectives for EMC, Low Voltage, Machinery and Boiler Efficiency.All the Riello 40 G burners are fired before leaving the factory.

TS0024UK01

ONE STAGE LIGHT OIL BURNERS RIELLO 40 G SERIES G3 23,8 ÷ 35,9 kWG3R 23,8 ÷ 35,9 kWG3RK 15,0 ÷ 35,0 kWG5 28,0 ÷ 60,0 kWG5R 28,0 ÷ 60,0 kWG5K 29,0 ÷ 60,0 kWG5RK 12,0 ÷ 60,0 kWG7 29,0 ÷ 69,0 kWG10 54,0 ÷ 120,0 kWG20 95,0 ÷ 213,0 kWG20S 95,0 ÷ 240,0 kW

Page 2

FIRING RATES

0
0,1

kW36
1,4

0,2
0,3
0,4
0,5
0,6
0,7
0,8
0,9

1

1,6 1,8 2,0 2,2 3,02,4 2,6 2,8
34323028262422201816

0
0,1

kW
1,0

0,2
0,3
0,4
0,5
0,6
0,7
0,8
0,9

Useful working field for choosing the burner
Test conditions conforming to EN 267:Temperature: 20°CPressure: 1013.5 mbarAltitude: 100 m a.s.l.

10

0
1
2
3
4
5
6
7
8
9

0
1
2
3
4
5
6
7
8
9

1,2

1,5 2,52,0 3,0 5,03,5 4,0 4,5

15 20 25 30 35 40 45 50 55 6010

14

G3RK

G5G5RG5RK

hPa
(m

bar
)

mm
H 2

O

hPa
(m

bar
)

mm
H 2

O

kg/h

kg/h

G3G3R

G5K

Page 163

FIRING RATES

0

5

15

25

20

10

-5

30

40

35

45

m
m

H
2
O

-10

0

2

3

1

4
h

P
a

(
m

b
a

r)

- 1

- 0,5

0,5

1,5

2,5

3,5

4,5

100 200 300

0

0
kW

3010 20
kg/h

RL 28/1

Useful working field for choosing the burner

Test conditions conforming to EN 267:
Temperature: 20°C
Pressure: 1013.5 mbar
Altitude: 100 m a.s.l.

Page 164

HYDRAULIC CIRCUITS

FUEL SUPPLY

The burner is fitted with a self-priming pump and two delivery
valves along the oil line from the pump to the nozzles.
The pump does not need calibrating, as it is set in the factory
at 12 bar; however, pressure level can be changed if necessary,
by adjusting the regulator fitted on the pump.
The delivery valves control the passage from starting to
operating phase.
At the start, after pre-purging phase, the first delivery valve
opens and the fuel is sprayed out through the first nozzle,
igniting when it comes into contact with the spark; then the
second delivery valve opens and the fuel is sprayed out
through both nozzles.

Example of self-priming pump of RL 28/1burners

V P

P

V1

V2

U1

U2

Pump with filter and pressure regulator

1st delivery valve

2nd delivery valve

1st nozzle

2nd nozzle

Hydraulic layout of RL 28/1 burner

V2 V1 U1U2

P

Page 326

PRODUCT SPECIFICATIONS
Burner:Monoblock forced LOW NOx oil burner with completely automatic two stage setting, made up of:- air suction circuit lined with sound-deadening material- fan with reverse curve blades high performance with low sound emissions- air damper for air setting, driven by the adjustable servomotor- starting motor at 2800 rpm, single-phase, 230V and 50Hz- low emission combustion head, that can be set on the basis of required output, fitted with:- stainless steel end cone, resistant to corrosion and high temperatures- ignition electrodes- flame stability disk- gears pump for high pressure fuel supply, fitted with:- filter- pressure regulator- connections for installing a pressure gauge and vacuometer- internal by pass for single pipe installation- two oil valves fitted directly on to the pump- photocell for flame detection- flame control panel- electronic device to check all burners operational modes (status panel)- burner on/off switch- manual high/low flame switch- flame inspection window- slide bars for easier installation and maintenance- protection filter against radio interference- IP 44 electric protection level.
According to:- 89/336/EEC directive (electromagnetic compatibility)- 73/23/EEC directive (low voltage)- 92/42/EEC directive (performance)- 98/37/EEC directive (machinery)- EN 267 (liquid fuel burners)- LRV '92.
Standard equipment:- 1 nozzle- 2 flexible pipes for connection to the oil supply network- 2 gaskets for the flexible pipes- 2 nipples for connection to the pump- 1 thermal screen- 4 screws for fixing the burner flange to the boiler- wiring loom fittings for electrical connections- instruction handbook for installation, use and maintenance- spare parts catalogue.
Available accessories to be ordered separately:- nozzles- head extension kit- sound-proofing box- degassing unit.

Page 327

RIELLO S.p.A. - Via degli Alpini, 1 - 37045 LEGNAGO (VR) Italy
Tel. ++39.0442630111 - Fax ++39.044221980

Internet: http://www.rielloburners.com - E-mail: [email protected] 9001 Cert. n. 0061
Since the Company is constantly engaged in the production improvement, the aesthetic anddimensional features, the technical data, the equipment and the accessories can be changed.This document contains confidential and proprietary information of RIELLO S.p.A.Unless authorised, this information shall not be divulged, nor duplicated in whole or in part.