Download NX-Nastran-Error-List PDF

TitleNX-Nastran-Error-List
File Size2.3 MB
Total Pages224
Table of Contents
                            Information, Warning, Error Messages
Error Messages 1-1000
Error Messages 1001-2000
Error Messages 2001-3000
Error Messages 3001-4000
Error Messages 4001-5000
Error Messages 5001-6000
Error Messages 6001-7000
Error Messages 7001-8000
Error Messages 9001-10000
OTHER ERROR MESSAGES
                        
Document Text Contents
Page 1

www.c
The do
NX Nastran

Error List
adfamily.com EMail:[email protected]
cument is for study only,if tort to your rights,please inform us,we will delete

www.cadfamily.com

Page 2

www.cadfam
The docume
Proprietary & Restricted Rights Notice

 2005 UGS Corp. All Rights Reserved. This software and related documentation are proprietary to
UGS Corp. LIMITATIONS TO U.S. GOVERNMENT RIGHTS. UNPUBLISHED - RIGHTS RESERVED
UNDER THE COPYRIGHT LAWS OF THE UNITED STATES. This computer software and related
computer software documentation have been developed exclusively at private expense and are
provided subject to the following rights: If this computer software and computer software
documentation qualify as “commercial items” (as that term is defined in FAR 2.101), their use,
duplication, or disclosure by the U.S. Government is subject to the protections and restrictions as set
forth in the UGS Corp. commercial license for the software and/or documentation as prescribed in FAR
12.212 and FAR 27.405(b)(2)(i) (for civilian agencies) and in DFARS 227.7202-1(a) and DFARS 227.7202-
3(a) (for the Department of Defense).,or any successor or similar regulation, as applicable or as
amended from time to time. If this computer software and computer documentation do not qualify as
“commercial items,” then they are “restricted computer software,” and are provided with “restrictive
rights,” and their use, duplication or disclosure by the U.S. Government is subject to the protections and
restrictions as set forth in FAR 27.404(b) and FAR 52-227-14 (for civilian agencies), and DFARS
227.7203-5(c) and DFARS 252.227-7014 (for the Department of Defense), or any successor or similar
regulation as applicable or as amended from time to time. UGS Corp. , Suite 600 - 5800 Granite
Parkway, Plano, Texas 75024.

NASTRAN is a registered trademark of the National Aeronautics and Space Administration. NX
Nastran is an enhanced proprietary version developed and maintained by UGS Corp.

MSC is a registered trademark of MSC.Software Corporation. MSC.Nastran and MSC.Patran are
trademarks of MSC.Software Corporation.

All other trademarks are the property of their respective owners.
ily.com EMail:[email protected]
nt is for study only,if tort to your rights,please inform us,we will delete

www.cadfamily.com

Page 112

www.cad
The docu
IN CASE CONTROL DECK FOR CYCLIC SYMMETRY ANALYSIS BUT IS NOT
SUPPLIED BY USER.
4315 *** USER FATAL MESSAGE 4315, OVERALL SYMMETRY OPTION IS
NOT ALLOWED UNDER ROT OR AXI CYCLIC SYMMETRY ANALYSIS.
4316 *** USER FATAL MESSAGE 4316, GRID POINT ID, *** WHICH LIES
ON THE AXIS OF SYMMETRY IS ILLEGALLY DEFINED AS A SIDE 1 OR SIDE
2 POINT BY MEANS OF A CYJOIN CARD.
4317 *** USER FATAL MESSAGE 4317, GRID POINT ID, ***, WHICH LIES
ON THE AXIS OF SYMMETRY SHOULD NOT BE CONSTRAINED BY MULTI-
POINT CONSTRAINT SET.
4318 *** USER FATAL MESSAGE 4318, GRID POINT ID, ***, WHICH LIES
ON THE AXIS OF SYMMETRY HAS ILLEGALLY DEFINED SPC CON-
STRAINTS.
4319 *** USER FATAL MESSAGE 4319, GRID POINT ID, ***, AND COMPO-
NENT ID, ***, WHICH IS DEFINED IN CYSUP BULK DATA CARD, HAS BEEN
ILLEGALLY DEFINED ON SPC, SPC1, OMIT, OMIT1 CARDS, OR IN RIGID
ELEMENTS OR MULTIPOINT CONSTRAINTS AS DEPENDENT COORDI-
NATES.
4320 *** USER FATAL MESSAGE 4320, GRID POINT ID, ***, DEFINED IN
CYSUP BULK DATA CARD IS ILLEGAL. FOR DIHEDRAL SYMMETRY, THIS
GRID POINT SHOULD BE A SIDE 1 POINT AND FOR ROTATIONAL SYMME-
TRY THIS GRID POINT SHOULD NOT BE DEFINED ON THE AXIS OF SYM-
METRY OR ON SIDE 2.
4321 *** USER WARNING MESSAGE 4321, SOME VALUES OF THE HAR-
MONICS SPECIFIED FOR ANALYSIS IN THE HARMONICS CARD ARE
GREATER THAN THE MAXIMUM VALUE PERMISSIBLE. VALUES OF HAR-
MONICS GREATER THAN NSEG/2 WILL NOT BE USED IN THE ANALYSIS.
4326 *** USER INFORMATION MESSAGE 4326, USER SUPPLIED LOAD-
CYH AND GRAV CARDS ARE REPLACED AS FOLLOWS:
4327 *** USER INFORMATION MESSAGE 4327, USER SUPPLIED LOAD-
CYH AND RFORCE CARDS ARE REPLACED AS FOLLOWS:
4328 *** USER WARNING MESSAGE 4328, THE ANISOTROPIC MATERIAL
PROPERTY FOR MEMBRANE ACTION DEFINED BY MAT2 ID ******** IS
INCONSISTENT WITH CONICAL SHELL THEORY. G13 AND G23 WILL BE
SET TO ZERO ***
4329 *** USER WARNING MESSAGE 4329, THE ANISOTROPIC MATERIAL
PROPERTY FOR BENDING ACTION DEFINED BY MAT2 ID ******** IS INCON-
SISTENT WITH CONICAL SHELL THEORY. G13 AND G23 WILL BE SET TO
ZERO *** PROPERTY FOR TRANSVERSE SHEAR ACTION DEFINED BY
MAT2 ID ******** IS INCONSISTENT WITH CONICAL SHELL THEORY. G12
WILL BE SET TO ZERO ***
4334 *** USER FATAL MESSAGE 4334, NEGATIVE-DEFINITE MASS
MATRIX FOUND IN DYNAMIC REDUCTION.

Generalized dynamic reduction assumes a non-negative definite mass matrix. This prevents
computation of modes with negative generalized mass. User input of negative mass, large off-
diagonal mass terms, or requesting more modes than there are independent degrees of freedom
with mass can lead to this condition.
Inspect the input mass data for the conditions described above, or reduce FMAX if the number of
degrees of freedom with mass is not adequate.

4335 *** USER FATAL MESSAGE 4335, MORE THAN ONE SUPPORT
POINT IS ILLEGALLY DEFINED IN THE MODEL, WHERE ONLY ONE IS
ALLOWED. THE LIST OF POINTS REFERENCED BY CYSUP BULK DATA
CARDS FOLLOWS:

Only one support point allowed in Cyclic Symmetry Analysis. Delete all support points (except
one).

family.com EMail:[email protected]

ment is for study only,if tort to your rights,please inform us,we will delete

www.cadfamily.com

Page 113

www.cad
The docu
4336 *** USER FATAL MESSAGE 4336, NO CYSYM CARD FOUND.

CYSYM Bulk Data entry is required to perform cyclic symmetry analysis. Define CYSYM Bulk
Data entry.

4337 *** USER FATAL MESSAGE 4337, HARMONICS SET SPECIFIED ON
HOUTPUT CASE CONTROL CARD IS UNDEFINED.

The HOUTPUT Case Control command defines the values of harmonics for which output will be
produced. The set ID specified by this command is not defined in Case Control.

4338 *** USER FATAL MESSAGE 4338, SEGMENTS SET SPECIFIED ON
NOUTPUT CASE CONTROL CARD IS UNDEFINED.

The NOUTPUT Case Control command defines the values of segments for which output will be
produced. The set ID specified by this command is not defined in Case Control Section.

4339 *** USER FATAL MESSAGE 4339, HARMONICS SET SPECIFIED ON
NOUTPUT CASE CONTROL CARD IS UNDEFINED.

In the solution of vibration problems, the segment output can be selected for a specified set of
harmonics.
The set of harmonics specified in the NOUTPUT Case Control command is not defined in the
Case Control.

4340 *** USER FATAL MESSAGE 4340, LINEAR COMBINATION OF SUB-
CASES NOT ALLOWED IN CYCLIC SYMMETRY ANALYSIS.

SUBCOMS and/or SYMCOMS are not allowed in cyclic symmetry analysis. Delete requests of
SUBCOMS and/or SYMCOMS.

4341 *** USER FATAL MESSAGE 4341, HARMONICS SET SPECIFIED FOR
ANALYSIS IS UNDEFINED.

The values of harmonics for which analysis will be performed is given by the set specified in the
HARMONICS Case Control Section. This set is not defined. Define the set of integer values of
harmonics for analysis.

4342 *** USER FATAL MESSAGE 4342, THE LOAD BULK DATA CARD
GIVEN BELOW, IS INCONSISTENT WITH SPECIFIED ANALYSIS HARMON-
ICS OR SEGMENTS OR SYMMETRY TYPE.

The load specified by LOADCYH Bulk Data entry should specify loading for harmonics that are
valid for the problem. For example, the integer value of the harmonics that are loaded should be
contained in the analysis harmonics set and furthermore the harmonic type should also be con-
tained in analysis harmonics type. If not, this fatal message will result. Similarly, the load speci-
fied by LOADCYN Bulk Data entry should specify loading for segments that are in the model. In
addition, if symmetry option is used in DIHEDRAL type problems, the load should be applied in
segments in the first half-plane (or quadrant) of the model. Specify valid harmonic loading or
segment loading.

In buckling problems, the static pre-load must be the same for all segments, which is ensured by
providing a zero (cosine) harmonic loading. For such problems, this fatal message will result if
the loading is specified any other way than via LOADCYH entry.

See also Error Report 3502.
4343 *** USER FATAL MESSAGE 4343, LOAD ID=*** WAS ILLEGALLY
REFERENCED BY BOTH LOADCYH AND LOADCYN CARDS.

family.com EMail:[email protected]

ment is for study only,if tort to your rights,please inform us,we will delete

www.cadfamily.com

Page 223

www.cad
The docu
CURVX.
FILE NUM=****. CONSTRAINTS IN COMMON /CURVTB/

*** USER WARNING MESSAGE (CURVIT-1) LOCAL INTERPOLATION USING
INDEPENDENT VALUES WITHIN RANGE OF THE ******-TH SORTED ORDER
GRID ID INVOLVED WITH RESPECT TO MATERIAL COORDINATE SYSTEM
ID=*******CANNOT BE COMPLETED. ILL-CONDITION MAY HAVE RESULTED
FROM ALIGNMENT OF INDEPENDENT VALUE COORDINATES. OUTPUT
FOR THE GRID ID IN QUESTION WILL NOT APPEAR.

*** SYSTEM FATAL MESSAGE (ELFDR) SUBROUTINE ELFDRX HAS
RETURNED WITH ERROR CONDITION ***********LOC CODE=****** IN SUB-
ROUTINE ELFDRS. FILE NUM=**** (MAY BE INCONSEQUENTIAL) (NOTE
ADDITIONAL MESSAGES) CONSTRAINTS IN COMMON /ELFDRT/BUG
PRINTED 5000 LINES. NO MORE BUG MESSAGES. EXECUTION CONTIN-
UES

*** USER FATAL MESSAGE, DOM3A. NO MATCH FOUND BETWEEN DVlDR
DESVAR IDS AND DVTM lDS

*** SYSTEM FATAL MESSAGE 71 XX, DOM2L. DOPTPRM RECORD OF
EDOM IS LESS THAN 17 WORDS LONG

*** SYSTEM FATAL MESSAGE 71 XX, DOM2L. END OF FILE ENCOUN-
TERED IN EDOM 6.3.7

MORE THAN 50 CONTOURS SPECIFIED ******* REJECTED CARD STARTING
WITH ****** IGNORED AN UNRECOGNIZABLE OPTION ****** WAS
DETECTED ON A -PLOT- CARD A NONEXISTENT ORIGIN ******** IS SPECI-
FIED ON A -PLOT- CARD A NONEXISTENT SET ******** iS SPECIFIED. PLOT
FRAME IS NULL.

THE -PLT2- PLOT TAPE HAS NOT BEEN SET UP. PLOT CARD IGNORED.

INSUFFICIENT CORE FOR SET ********. CORE AVAILABLE=********,
NEEDED=***** INSUFFICIENT CORE CONBDR ELEMENT***** NO STRESS
CALCULATIONS FOUND FOR ELEMENT NUMBER****** - ELEMENT
IGNORED ALL REFERENCES TO SET ******* WILL BE IGNORED NO SETS
EXIST - PLOTS SKIPPED AN ATTEMPT HAS BEEN MADE TO DEFINE MORE
THAN lo DISTINCT ORIGINS REFERENCE TO SET ****** ON FIND CARD
WILL DEFAULT TO FIRST DEFINED SET AN UNRECOGNIZABLE REQUEST
******* HAS BEEN SPECIFIED ON A -FIND- CARD INSUFFICIENT CORE SUB-
ROUTINE FIND. CORE NEEDED=******** AVAILABLE****** AN UNRECOG-
NIZABLE PLOT PARAMETER ******** HAS BEEN DETECTED - IGNORED AN
INVALID PLOTTER ******** HAS BEEN SPECIFIED - THE CURRENT PLOTTER
WILL BE USED INSTEAD PEN **** IS NOT A LEGAL PEN NUMBER FOR THIS
PLOTTER. PEN l WILL BE REDEFINED.

INCOMPLETE PLOT DUE TO INPUT OF FILE A PLOT NOT ATTEMPTED DUE
TO INPUT OR FILE NO SETS EXIST IN PLOT PACKAGE CARD STARTING
WITH ******* IGNORED NO PLOTABLE STRUCTURAL ELEMENTS EXIST IN
SET***** CONNECT IGNORING ELEMENT ******** WITH MORE THAN 20
CONNECTIONS ******** ELEMENTS CANNOT BE PLOTTED BY THE STRUC-
TURAL PLOTTER *** USER WARNING MESSAGE --- CHBDY ELEMENT
******* HAS NO NORMAL OR BAD GEOMETRY WHICH MAKES IT UNPLOTA-
BLE 6.3.7.3

Logic Error Messages The following are logic error messages and they usually result from an
family.com EMail:[email protected]

ment is for study only,if tort to your rights,please inform us,we will delete

www.cadfamily.com

Page 224

www.cad
The docu
error in the program. The complete run should be sent to the programming staff for analysis and
program correction.

SET ******* RESULTED IN ILLEGAL EOF IN GPSTETS FILE ELEMENT TYPE
******* WITH ******* GRIDS SKIPPED IN LINEL INCOMPLETE PLOT DUE TO
INPUT OR FILE SUPLT REJECTED PLOT. PIVOT ******* IS ZERO OR SAME
AS ENTRY SUPLT REJECTED PLOT, NEGATIVE NUMBER ENTRIES -N3,N4-
******** ******** UNEXPECTED EOF IN SUPLE - PIVOT****** SUPLT - ENTRY
******** FOR PIVOT NOT FOUND ******** RANGE NO ELEMENTS IN THIS SET

*** SYSTEM FATAL MESSAGE XXXX, FILE ******* NOT IN FIST.
File not in fist coding error.*** USER FATAL MESSAGE lFPi XY-1. ABOVE CARD MUST END
WITH ONE INTEGER VALUE.

SEPLOT card in XYPLOT package must have a superelement ID.

Abnormal Termination NX Nastran may terminate as a result of errors detected by the operating
system or by the NX Nastran code. lf DIAG 44 is set, then NX Nastran will produce a dump when
most of the errors occur. The purpose of these remarks is to aid the user in interpreting the out-
put which accompanies these types of errors.
An example of this type of output with some commentary is presented on the following pages.
Specific items of this output are denoted with circled numbers for reference purposes:

family.com EMail:[email protected]

ment is for study only,if tort to your rights,please inform us,we will delete

www.cadfamily.com

Similer Documents