Download HLR9820-Configuration Guide(V900R003C02 04,Db2) PDF

TitleHLR9820-Configuration Guide(V900R003C02 04,Db2)
Tags Database Index Databases Command Line Interface
File Size1000.3 KB
Total Pages105
Table of Contents
                            Contents
Figures
Tables
About This Document
1 Overview of Data Configuration
	1.1 Data Configuration Process
	1.2 Introduction to MML Commands
		1.2.1 Meanings of Common MML Commands
		1.2.2 Rules for Setting MML Command Parameters
		1.2.3 Data Setting Procedures
	1.3 Precautions for Data Configuration
		1.3.1 Impact of the Maximum Number of Tuples on Data Configuration
		1.3.2 Impact of Value Ranges of Software Parameters on Data Configuration
		1.3.3 Impact of Software Parameters on Data Configuration
		1.3.4 Impact of Board Restarting on Data Configuration
2 Hardware Data Configuration
	2.1 Basic Concepts
		2.1.1 Rack Number
		2.1.2 Subrack Number
		2.1.3 Slot Number
		2.1.4 Module Number
		2.1.5 Cluster
		2.1.6 Node
	2.2 Data Configuration Flow Chart
	2.3 Hardware Data Table Relation
	2.4 Data Configuration Procedure
		2.4.1 Adding a Rack
		2.4.2 Adding an OSTA 1.0 Subrack
		2.4.3 Setting the OSTA 1.0 Board Type
		2.4.4 Adding an OSTA 1.0 Board
		2.4.5 Configuring the Hardware Data in TDM Networking
		2.4.6 Configuring the Hardware Data in IP Networking
		2.4.7 Configuring the Hardware Data in ATM-2M Networking
		2.4.8 Adding an OSTA 2.0 Subrack
		2.4.9 Adding an OSTA 2.0 Board
		2.4.10 Setting the Local Office Information
		2.4.11 Adding the Cluster Configuration
		2.4.12 Adding the Node Configuration
		2.4.13 Setting the HDU Configuration
		2.4.14 Adding the Remote Node Configuration
		2.4.15 Adding the MEM Configuration
		2.4.16 Generating SAU Data Loading Files
		2.4.17 Synchronizing the HDU Configuration
	2.5 Data Configuration Examples
		2.5.1 Data Configuration in TDM Networking
		2.5.2 Data Configuration in ATM-2M Networking
		2.5.3 Data Configuration in IP Networking
3 Local Office Data Configuration
	3.1 Basic Concepts
		3.1.1 Local Office Information
		3.1.2 Called Prefix
		3.1.3 SPC
	3.2 Data Configuration Procedure
	3.3 Data Configuration Example
		3.3.1 Description
		3.3.2 Example
4 Signaling Data Configuration
	4.1 Basic Concepts
		4.1.1 MTP-Specific Concepts
		4.1.2 MTP3B-Specific Concepts
		4.1.3 SIGTRAN-Specific Concepts
		4.1.4 SCCP-Specific Concepts
		4.1.5 Signaling Data Configuration Principles
	4.2 Data Configuration Procedures
		4.2.1 Data Configuration Procedure in TDM Networking
		4.2.2 Data Configuration Procedure in ATM-2M Networking
		4.2.3 Data Configuration Procedure in IP Networking
	4.3 MTP Data Configuration Procedure
	4.4 MTP3B Data Configuration Procedure
	4.5 M3UA Data Configuration Procedure
	4.6 SCCP Data Configuration Procedure
		4.6.1 SCCP Data Configuration Principles
		4.6.2 SCCP Data Table Relation
	4.7 Data Configuration Examples
		4.7.1 Data Configuration in TDM Networking
		4.7.2 Data Configuration in ATM-2M Networking
		4.7.3 Data Configuration in IP Networking
A Abbreviations
Index
                        
Document Text Contents
Page 1

HUAWEI HLR9820 Home Location Register

V900R003C02

Configuration Guide

Issue 04

Date 2009-01-15

Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.

Page 2

Huawei Technologies Co., Ltd. provides customers with comprehensive technical support and service. For any
assistance, please contact our local office or company headquarters.



Huawei Technologies Co., Ltd.
Address: Huawei Industrial Base

Bantian, Longgang
Shenzhen 518129
People's Republic of China

Website: http://www.huawei.com

Email: [email protected]







Copyright © Huawei Technologies Co., Ltd. 2009. All rights reserved.
No part of this document may be reproduced or transmitted in any form or by any means without prior written
consent of Huawei Technologies Co., Ltd.

Trademarks and Permissions

and other Huawei trademarks are the property of Huawei Technologies Co., Ltd.
All other trademarks and trade names mentioned in this document are the property of their respective holders.

Notice
The information in this document is subject to change without notice. Every effort has been made in the
preparation of this document to ensure accuracy of the contents, but the statements, information, and
recommendations in this document do not constitute a warranty of any kind, express or implied.

Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.

http://www.huawei.com

Page 52

Operation
Client

Data Configuration
Procedure

Command

Add the unstructured
supplementary service
data (USSD).

ADD USSDDAT

Add the called number
analysis data.

ADD CALLEDNA

Set the FTN conversion
rule.

SET FTNTRANS

Add the information of an
FTN.

ADD FTNNCS

Set the default notification
to calling subscriber
(NCS) attributes.

SET DEFNCS

Add the CAMEL-
Roaming-Agreement
template.

ADD CAMELROAMTPL

Add the CAMEL-
Interrogation-Agreement
template.

ADD CAMELINTERTPL

Set the default NCC
template for the VLR and
the SGSN.

SET DEFNCC

Set the FTN segment
restriction.

SET BWFTN

Set the short message
center (SMC) address
restriction.

SET BWADDR

Set the roaming restriction
state of the subscribers
defined in the HLR.

MOD HLRRR

Configure the service
entity list.

SET SELIST

Configure the alternative
handling of unsupported
services.

SET NONSUPHND

3.3 Data Configuration Example

3.3.1 Description

3.3.2 Example

3 Local Office Data Configuration
HUAWEI HLR9820 Home Location Register

Configuration Guide

3-4 Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.

Issue 04 (2009-01-15)

Page 105

Index

B
basic concept

called prefix, 3-2
cluster, 2-6
local office information, 3-2
MTP-Specific, 4-2
MTP3B-Specific, 4-10
node, 2-6
rack number, 2-2
SCCP-Specific, 4-16
SIGTRAN-Specific, 4-13
slot number, 2-4
SPC, 3-2

D
data configuration process, 1-2

hardware data configuration, 2-1
local office data configuration, 3-1
signaling data configuration, 4-1

H
hardware data configuration

adding cluster configuration information, 2-13
adding node configuration, 2-14
adding OSTA 1.0 board, 2-12
adding OSTA 1.0 subrack, 2-12
adding OSTA 2.0 board, 2-13
adding OSTA 2.0 subrack, 2-13
adding rack, 2-12
flow chart, 2-7
generating SAU data loading file, 2-14
hardware data table relation, 2-9
setting local office information, 2-13
synchronizing HDU configuration, 2-14

hardware data configuration example
ATM-2M networking, 2-19
TDM networking, 2-15

I
impact on data configuration

board restarting, 1-8
maximum number of tuple, 1-6
software parameter, 1-8
value ranges of software parameter, 1-7

L
local office data configuration example, 3-5

M
MML command

data setting procedure, 1-4
meaning, 1-2
rule, 1-3

S
signaling data configuration

M3UA data configuration, 4-27
MTP data configuration, 4-24
MTP3B data configuration, 4-26
SCCP data configuration, 4-28

signaling data configuration example
ATM-2M networking, 4-32
IP networking, 4-33
TDM networking, 4-30

signaling data configuration procedure
ATM-2M networking, 4-22
IP networking, 4-23
TDM networking, 4-21

HUAWEI HLR9820 Home Location Register
Configuration Guide Index

Issue 04 (2009-01-15) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.

i-1

Similer Documents